AM2-B0-24-610-301-I [Carling Technologies]
Magnetic Circuit Breaker,;型号: | AM2-B0-24-610-301-I |
厂家: | Carling Technologies |
描述: | Magnetic Circuit Breaker, 电路保护 |
文件: | 总28页 (文件大小:3956K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
A
A-
riesSeries
-Se
CIRCUIT BREAKER
Well known for their proven reliability, Carling Technologies’ A-Series hydraulic magnetic circuit breakers are
compact, temperature stable and designed for precision operation in OEM markets requiring general purpose
as well as full load amp applications. When front panel operation and aesthetics demand a clean, contemporary
design, the visi-rocker or paddle actuators are ideally suitable. A sealed toggle actuator style is also available and
ideal for harsh environment applications requiring additional sealing protection. Optional rocker-guard and push-
to-reset bezels, which help prevent inadvertent actuation, are also available.
1-6 poles; ratings from 0.02 to 50 amps, up to 277VAC or 80VDC; UL Recognized, UL Listed, UL1500, UL1077,
TUV, VDE & CSA
Resources:
Configure a Complete Part
Download CAD & Sales Drawing
Product Highlights:
•ꢀ Upꢀtoꢀ50ꢀampsꢀinꢀaꢀcompactꢀsize
•ꢀ Variousꢀactuatorꢀstyles
Typical Applications:
•ꢀ Telecomꢀ/ꢀDatacom
•ꢀ Marine
•ꢀ Sealedꢀmetalꢀtoggleꢀoptionꢀtestedꢀtoꢀ
ꢀ MIL-PRF-55629C.ꢀMeetsꢀIP68ꢀ
ꢀ Requirements
•ꢀ Military
•ꢀ RenewableꢀEnergy
•ꢀ Generatorsꢀ&ꢀWelder
Carling Technologies, Inc.
60 Johnson Avenue, Plainville, CT 06062
Email: sales@carlingtech.com
Application Support: team2@carlingtech.com
Phone: 860.793.9281 Fax: 860.793.9231
www.carlingtech.com
|
2
A-Series Circuit Breaker – General Specifications
Electrical
Maximum Voltage
Current Ratings
Mechanical
277VAC 50/60 Hz, 80VDC
Standard current coils: 0.100,
0.250, 0.500, 0.750, 1.00, 2.50,
5.00, 7.50, 10.0, 15.0, 20.0, 25.0,
30.0, 35.0, 40.0, 50.0. Other ratings
available - consult ordering
scheme.
Endurance
10,000 ON-OFF operations @ 6 per
minute; with rated Current & Voltage.
All A-Series Circuit Breakers will trip
on overload, even when the actuator
is forcibly held in the ON position.
The operating actuator moves
positively to the OFF position when
an overload causes the circuit
breaker to trip. When mid-trip
Trip Free
Trip Indication
Standard Voltage Coils DC-6V, 12V; AC-120V, Other ratings
available, consult ordering scheme.
Auxiliary Switch Rating SPDT; 10.1 A - 250VAC,
1.0 A-65VDC/0.5 A - 80 VDC,
handle is specified, the handle
moves to the mid position on
0.1A - 125VAC (with gold contacts).
Minimum: 100 Megohms at 500
VDC
electrical trip of the circuit breaker.
When mid-trip handle with alarm
switch is specified, the handle
moves to the mid position & the
alarm switch actuates when the
circuit breaker is electrically tripped.
Insulation Resistance
Dielectric Strength
UL, CSA - 1500V 60 Hz for one
minute between all electrically
isolated terminals. A-Series rocker
circuit breakers comply with the
8mm spacing & 3750V dielectric
requirements from hazardous
voltage to operator accessible
surfaces per EN 60950 and VDE
0805.
Physical
Number of Poles
1 - 6 Poles (handle) and 1-3 poles
(rocker) at 30 Amps or less. 1 and 2
poles at 31 Amps thru 50 Amps.
Internal Circuit Config. Series, (with or without auxiliary
switch), Shunt and Relay with current
or voltage trip coils, Dual Coil,
Resistance, Impedance Values from Line to Load Terminal
- based on Series Trip Circuit
Breaker.
Switch Only with or without auxiliary
switch.
Approximately 65 grams/pole.
(Approximately 2.32 ounces/pole)
Housing - Black; Actuator- See
Ordering Scheme.
RESISTANCE PER POLE VALUES
from Line to Load Terminals
(Values Based on Series Trip Circuit Breaker)
Weight
Standard Colors
CURRENT
(AMPS)
TOLERANCE
(%)
0.10 - 5.0
5.1 - 20.0
20.1 - 50.0
15
25
35
Environmental
Designed and tested in accordance with requirements of
specification MIL-PRF-55629 & MIL-STD-202 as follows:
Shock
Withstands 100 Gs, 6ms, sawtooth
while carrying rated current per
Method 213, Test Condition “I”.
Instantaneous and ultra-short curves
tested @ 90% of rated current.
Withstands 0.060” excursion from
10-55 Hz, and 10 Gs 55-500 Hz,
at rated current per Method 204C,
Test Condition A. Instantaneous and
ultrashort curves tested at 90% of
rated current.
Vibration
Pulse Tolerance Curves
Moisture Resistance
Method 106D; ten 24-hour cycles @
+ 25°C to +65°C, 80-98% RH.56
days @ +85°C, 85% RH.
Salt Spray
Method 101, Condition A (90-95%
RH @ 5% NaCl Solution, 96 hrs).
Method 107D, Condition A (Five
cycles @ -55°C to +25°C to +85°C to
+25°C).
Thermal Shock
Operating Temperature -40° C to +85° C
*Manufacturer reserves the right to change product specification without prior notice.
Email: sales@carlingtech.com Application Support: team2@carlingtech.com
Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com
|
3
A-Series Circuit Breaker – General Specifications
Electrical Tables
Table A: Lists UL Recognized & CSA Accepted configurations and performance capabilities as a Component Supplementary Protector.
A-SERIES TABLE A: COMPONENT SUPPLEMENTARY PROTECTORS
Voltage
Current Rating
Short Circuit Capacity (Amps)
UL / CSA
Application Codes
Circuit
Configuration
Construction
Notes
General
Purpose
Amps
Max
Rating
Full Load
Amps
Frequency Phase
With Backup
Without
Backup Fuse
UL
CSA
TC1, OL1, U2
Fuse
32
65
DC
DC
---
---
0.02 - 15
31 ꢀ 50
0.02 - 30
---
---
---
---
---
---
5000
7500
7500
TC1, OL1, U2
TC1, 2, OL1, U1 TC1, 2, OL1, U1
TC1, 2, OL1, U1 TC1, 2, OL1, U1
TC1, 2, OL0, U1 TC1, 2, OL0, U1
80
DC
---
---
0.02 - 30
1 ꢀ 50
31 ꢀ 50
---
---
---
---
---
---
---
---
---
---
---
7500
3000
2000
1000
3000
3000
1500
3000
3000
1000
---
Rocker Version
125
125
50 / 60
50 / 60
50 / 60
50 / 60
50 / 60
1
1
1 4
TC1, OL1, U2
TC1, OL1, U2
TC1, OL1, U2
TC1, OL1, U2
TC1, OL1, U2
TC3, OL1, U3
125
1 ꢀ 50
---
125 / 250
125 / 250
1 3 0.02 - 30
1 3 0.02 - 50
0.02 - 30
---
---
---
TC1, 2, OL1, U2 TC1, 2, OL1, U2
TC1, 2, OL1, U2 TC1, 2, OL1, U2
TC1, 2, OL0, U2 TC1, 2, OL0, U2
Rocker Version
Handle
Series
Single Pole Break
Two Pole Break
1
0.02 - 30
---
---
TC1, OL1, U2
TC1, 2, OL0, U1 TC1, 2, OL0, U1
TC1, OL1, U2 TC3, OL1, U3
TC1, OL1, U2
250
50 / 60
1 4
3
1 ꢀ 50
---
---
---
---
---
---
---
31 ꢀ 50
---
---
0.02 - 30
31 ꢀ 50
0.02 - 30
0.02 - 50
0.02 - 50
0.02 - 30
---
5000 2
2000 1
5000 1
---
---
---
---
---
---
---
---
---
---
---
---
---
5000 2
2000 1
5000 1
---
---
---
5000 2
5000 1
---
---
---
5000 2
5000 1
TC1, 2, OL1, C1 TC1, 2, OL1, C1
TC1, 2, OL1, C1 TC1, 2, OL1, C1
TC1, 2, OL1, C1 TC1, 2, OL1, C1
---
---
277
32
65
50 / 60
DC
DC
1
---
---
5000
7500
7500
7500
3000
2000
1000
3000
3000
1500
3000
3000
1000
---
---
---
7500
3000
3000
---
TC1, OL1, U2
TC1, OL1, U2
TC1, 2, OL1, U1 TC1, 2, OL1, U1
TC1, 2, OL1, U1 TC1, 2, OL1, U1
TC1, 2, OL0, U1 TC1, 2, OL0, U1
80
DC
---
Rocker Version
Rocker Version
0.02 - 30
TC1, OL1, U2
TC1, OL1, U2
TC1, OL1, U2
TC1, OL1, U2
TC1, OL1, U2
TC3, OL1, U3
125
50 / 60
1
1 ꢀ 50
---
125
125 / 250
125 / 250
50 / 60
50 / 60
50 / 60
1 4 0.02 - 30
1 3 0.02 - 30
1 3 0.02 - 50
---
---
---
TC1, 2, OL1, U1 TC1, 2, OL1, U1
TC1, 2, OL1, U2 TC1, 2, OL1, U2
Dual Coil
Single Pole Break
Two Pole Break
1
1
1
1 4
0.02 - 30
0.02 - 30
---
---
---
31 ꢀ 50
---
TC1, OL0, U2
TC1, OL1, U2
TC1, OL0, U2
TC1, OL1, U2
TC1, 2, OL0, U1 TC1, 2, OL0, U1
TC1, OL1, U2 TC3, OL1, U3
250
50 / 60
1 ꢀ 50
0.02 - 30
31 ꢀ 50
---
---
TC1, 2, OL1, C1 TC1, 2, OL1, C1
TC1, 2, OL1, C1 TC1, 2, OL1, C1
TC1, 2, OL1, U1 TC1, 2, OL1, U1
TC1, 2, OL1, U1 TC1, 2, OL1, U1
TC1, 2, OL1, U1 TC1, 2, OL1, U1
TC1, 2, OL1, U1 TC1, 2, OL1, U1
TC1, 2, OL1, C1 TC1, 2, OL1, C1
TC1, 2, OL1, C1 TC1, 2, OL1, C1
TC1, 2, OL1, U1 TC1, 2, OL1, U1
TC1, 2, OL1, U1 TC1, 2, OL1, U1
TC1, 2, OL1, U1 TC1, 2, OL1, U1
TC1, 2, OL1, C1 TC1, 2, OL1, C1
TC1, 2, OL1, C1 TC1, 2, OL1, C1
3
277
80
125 / 250
50 / 60
DC
50 / 60
1
---
1
1
3
0.02 - 30
0.02 - 30
0.02 - 30
0.02 - 30
0.02 - 30
0.02 - 30
0.02 - 30
---
---
---
---
---
---
---
Shunt
Relay
250
50 / 60
277
80
125 / 250
50 / 60
DC
50 / 60
1
---
---
7500
3000
3000
---
1 3 0.02 - 30
---
1
3
1
---
---
1
3
1
0.02 - 30
0.02 - 30
0.02 - 30
0.02 - 50
0.02 - 30
---
---
---
---
---
---
31 ꢀ 50
---
250
50 / 60
277
65
80
50 / 60
DC
DC
---
Switch Only
not applicable
250
277
50 / 60
50 / 60
0.02 - 50
0.02 - 30
31 ꢀ 50
Notes:
1
2
3
4
Requires branch circuit backup with a UL LISTED Type K5 or RK5 fuse (15A minimum) at no more than 4 times the rating of the protector.
Same as note 1, except that backup fuse is limited to 80 A maximum.
2 pole protector required (with one pole per power line) for: 125/250 VAC, 1 pole protector required for : 125 VAC, 1Ø Power System.
Satisfies the requirements of clause 11.2.8.2.5 of CSA STD C22.2 No 100 for the use of supplementary protectors with portable generators.
Email: sales@carlingtech.com Application Support: team2@carlingtech.com
Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com
|
4
A-Series Circuit Breaker – General Specifications
Electrical Tables
Table B: Lists UL Recognized, CSA Accepted, VDE & TUV Certified configurations & performance capabilities as a Component
Supplementary Protector.
1
3
2
3
2
3
2
Notes:
1
2
3
4
General Purpose Ratings for UL/CSA Only.
Requires branch circuit backup with a UL LISTED Type K5 or RK5 fuse (15A minimum) at no more than 4 times the rating of the protector.
Same as note 2, except that backup fuse is limited to 80 A maximum.
Satisfies the requirements of clause 11.2.8.2.5 of CSA STD C22.2 No 100 for the use of supplementary protectors with portable generators.
Email: sales@carlingtech.com Application Support: team2@carlingtech.com
Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com
|
5
A-Series Circuit Breaker – General Specifications
Electrical Tables
Table C: Lists UL Recognized, CSA Accepted configurations and performance capabilities as Protectors, Supplementary for Marine
Electrical and Fuel Systems (Guide PEQZ2, File E75596). Ignition Protected per UL 1500. UL Classified Small Craft Electrical Devices,
Marine in accordance with ISO 8846 (Guide UZMK, File MQ1515) as Marine Supplementary Protectors.
A-SERIES TABLE C: UL1500 (Marine Ignition Protected)
CURRENT
RATING
SHORT CIRCUIT
CAPACITY (AMPS)
VOLTAGE
APPLICATION CODES
CIRCUIT
CONFIGURATION
WITHOUT BACKUP
FUSE
MAX. RATING FREQUENCY
PHASE
FULL LOAD AMPS
UL
CSA
14 1
DC
32 1
DC
SERIES
---
---
---
1
0.02 - 50
0.02 - 50
0.02 - 50
0.02 - 50
0.02 - 50
0.02 - 30
5000
5000
3000
3000
3000
1500
TC1,OL1,U1
TC1,OL1,U2
TC1,OL1,U1
TC1,OL1,U2
TC1,OL1,U2
TC1,OL1,U1
TC1,OL1,U1
TC1,OL1,U2
TC1,OL1,U1
TC1,OL1,U2
TC1,OL1,U2
TC1,OL1,U1
65
125
DC
50 / 60
50 / 60
50 / 60
1 2
125 / 250
250
1
Notes:
1
2
Available with special catalog number only (consult factory).
2 pole protector required (with one per power line) for 125 / 250 VAC. 1 pole protector required for 125 VAC 1 phase power system
Table D: Lists UL Listed configurations and performance capabilities as Circuit Breakers for use in Communications Equipment
(Guide DITT, File E189195), under UL489A.
Notes:
1
Parallel Pole Construction
Agency Certifications
Component Supplementary
Protector under Class 3215 30,
File 047848 0 000 CSA
UL Recognized
UL Standard 1077
CSA Accepted
Component Recognition Program
as Protectors Supplementary
(Guide CCN/QVNU2, File E75596)
Standard C22.2 No. 235
Switches, Industrial Control
(Guide CCN/NRNT2, File E148683)
EN60934, under License No.
R72103448
UL Standard 508
UL Standard 1500
TUV Certified
VDE Certified
Protectors, Supplementary for
Marine Electrical & Fuel Systems
(Guide PEQZ2, File E75596)
Ignition Protection
EN60934, VDE 0642 under File
No. 10537
UL Listed
UL Standard 489A
Communications Equipment
(Guide CCN/DITT, File E189195)
Email: sales@carlingtech.com Application Support: team2@carlingtech.com
Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com
|
6
A-Series Circuit Breaker - Handle UL Recognized – Ordering Scheme
A A 3 B 0 10 450 1 B 1 C
8
9
10
Mounting/
Barriers
11
Agency
Approval
1
2
3
4
5
6
7
Terminal
Actuator
Color
Series
Actuator
Poles
Circuit
Aux/Alarm
Switch
Frequency
& Delay
Current Rating
1 SERIES
A
7 CURRENT RATING (AMPERES)
CODE AMPERES
020 0.020
025 0.025
030 0.030
035 0.035
040 0.040
045 0.045
050 0.050
055 0.055
060 0.060
065 0.065
070 0.070
075 0.075
080 0.080
085 0.085
090 0.090
095 0.095
210 0.100
215 0.150
220 0.200
225 0.250
230 0.300
235 0.350
240 0.400
245 0.450
250 0.500
255 0.550
260 0.600
265 0.650
270 0.700
275 0.750
280 0.800
285 0.850
290 0.900
295 0.950
410 1.000
512 1.250
415 1.500
517 1.750
420 2.000
522 2.250
527 2.750
430 3.000
435 3.500
440 4.000
445 4.500
450 5.000
455 5.500
460 6.000
465 6.500
470 7.000
475 7.500
480 8.000
485 8.500
490 9.000
495 9.500
610 10.000
710 10.500
611 11.000
711 11.500
612 12.000
712 12.500
613 13.000
614 14.000
615 15.000
616 16.000
617 17.000
618 18.000
620 20.000
622 22.000
624 24.000
625 25.000
630 30.000
1
2 ACTUATOR
A
B
S
T
Handle, one per pole
Handle, one per multipole unit
Mid-Trip Handle, one per pole
Mid-Trip Handle, one per pole & Alarm Switch
3 POLES
1
2
One
Two
3
4
Three
Four
5
6
Five
Six
4 CIRCUIT
8
2
3
3
3,4
635 35.000
A
B
C
D
E
Switch Only (No Coil)
Series Trip (Current)
Series Trip (Voltage)
Shunt Trip (Current)
Shunt Trip (Voltage)
F
G
H
Relay Trip (Current)
Relay Trip (Voltage)
Dual Coil with Shunt Trip
Voltage Coil
Dual Coil with Relay Trip
Voltage Coil
8
640 40.000
8
645 45.000
8
650 50.000
3
3
6
3,4
OR VOLTAGE COIL (NORMAL RATED VOLTAGE)
CODE AMPERES
K
A06
6 DC
A32 32 DC
A48 48 DC
A65 65 DC
J12 12 AC
J18 18 AC
J24 24 AC
J48 48 AC
J65
65 AC
A12 12 DC
A18 18 DC
A24 24 DC
K20 120 AC
L40 240 AC
5
5 AUXILIARY / ALARM SWITCH
5
7
S.P.S.T., 0.093 Q.C. Term.
(Gold Contacts)
S.P.S.T., 0.110 Q.C. Term.
(Gold Contacts)
S.P.S.T., 0.187 Q.C. Term.
S.P.D.T., 0.187 Q.C. Term.
J06
6 AC
0
1
2
4
without Aux Switch
S.P.D.T., 0.093 Q.C. Term.
S.P.D.T., 0.110 Q.C. Term.
S.P.D.T., 0.093 Q.C. Term.
(Gold Contacts)
9
8 TERMINAL
8
9
10
11
1
2
3
4
5
6
Push-On 0.250 Tab (Q.C.)
Screw 8-32 with upturned lugs
Screw 8-32 (Bus Type)
Screw 10-32 with upturned lugs
Screw 10-32 (Bus Type)
Screw 8-32 with upturned lugs
& 30° bend
E
F
Screw M4 (Bus Type)
Screw M5 with upturned lugs
& 30° bend
11
11
G
H
L
M
Q
R
Screw M5 (Bus Type) & 30° bend
Screw M5 (Bus Type)
0.250 Q.C./ Solder Lug
M6 Threaded Stud
6 FREQUENCY & DELAY
11
12
11
14
03
10
11
12
14
16
20
21
22
24
26
DC 50/60Hz, Switch Only
DC Instantaneous
DC Ultra Short
30
DC, 50/60Hz Instantaneous
DC, 50/60Hz Ultra Short
DC, 50/60Hz Short
31
32
34
36
42
44
46
52
54
56
7
8
9
Screw 8-32 (Bus Type)
& 30° bend
Screw 10-32 with upturned lugs
& 30° bend
Screw 10-32 (Bus Type)
& 30° bend
Push-In Stud
DC Short
DC, 50/60Hz Medium
DC, 50/60Hz Long
Screw M4 with upturned lugs
& 30° bend
Screw M4 (Bus Type)
& 30° bend
Printed Circuit Board Terminals
Push-On 0.110 Tab (Q.C.)
DC Medium
DC Long
50/60Hz Instantaneous
50/60Hz Ultra Short
50/60Hz Short
50/60Hz Medium
50/60Hz Long
7
7
7
7
7
7
50/60Hz Short, High-inrush
11
T
50/60Hz Medium, High-inrush
50/60Hz Long, High-inrush
13
13
P
S
DC, Short, High-inrush
B
C
Screw M5 with upturned lugs
Screw M4 with upturned lugs
DC, Medium, High-inrush
DC, Long, High-inrush
Notes:
9 ACTUATOR COLOR & LEGEND
1
Actuator Code:
Actuator Color
I-O
A
C
F
H
K
M
P
R
T
ON-OFF
Dual
Legend Color
Black
A: Handle tie pin spacer(s) and retainers provided un-assembled with multi-pole units.
B: Handle location as viewed from front of breaker:
White
B
D
G
J
1
2
3
4
5
6
7
8
9
2 pole - left pole
3 pole - center pole
4 pole - two handles at center poles
Black
White
5 pole - three handles at center poles
S: Handle moves to mid-position only upon electrical trip of the breaker. Available with
circuit codes B, C, D, E, F, G, H and K.
6 pole - four handles at center poles
Red
White
Green
White
Blue
L
White
T: Handle moves to mid-position and alarm switch activates only upon electrical trip of the
breaker. Available with circuit codes B & C.
Switch Only circuits, rated up to 50 amps and 6 poles, and only available when tied to a
protected pole (Circuit Code B, C, D or H.), For .02 to 30 amps,
Yellow
N
Q
S
U
Black
Gray
Black
2
Orange
Black
Black (short handle)15
White
select Current Code 630. For 35 - 50 amps, select Current Code 650.
Available with terminal Codes 1, 2 and 3. Current Rating limited to 50A amps maximum.
Consult factory for available Dual Coil options, as special catalog number is required.
With Shunt construction, Dual Coils will trip instantaneously on line voltage. Dual coils
require 30VA minimum power to trip and are rated for intermittent duty only.
Auxiliary Switch breakers with Series Trip & Switch Only circuits: ≤ 30A - supplied with
standard half shells. 35-50A - supplied with extended boat (B-Style) half shells.
On multi-pole breakers, one auxiliary switch is supplied, mounted in the extreme right pole.
Separate pole type voltage coils not rated for continuous duty. Available only with delay
codes 10 and 20.
3
4
10 MOUNTING / BARRIERS
MOUNTING STYLE
BARRIERS
5
Threaded Insert, 2 per pole
1
6-32 x 0.195 inches
6-32 x 0.195 inches
ISO M3 x 5mm
no
6
7
8
9
A
2
yes
no
Available with Circuit Codes B & D only. VDE Certified to 30 amps. UL Recognized, CSA
Accepted & TUV Certified to 50 amps.
B
ISO M3 x 5mm (multipole only)
yes
Front panel Snap-In, 0.75” wide bezel
without Handleguard
without Handleguard (multipole only)
Front panel Snap-In, 0.96” wide bezel
without Handleguard, 1-pole 0.96” wide;
multipole units have .105” bezel overhang on all sides
without Handleguard, 1-pole 0.96” wide;
(multipole only) .105” bezel overhang on all sides
VDE Certification available with single pole breakers with DC Delay only. UL Recognition
and CSAAccepted available in one and two pole breakers.
5
6
no
yes
Screw Terminals are recommended on ratings greater than 20 amps. Ratings over 30
amps are only available with Terminal Codes 5, 9, G, H, M and Q..
10 Terminal Code 1: VDE Certification up to 25 amps and UL Recognition and CSA
Certification up to 30 amps, but not recommended over 20 amps.
7
8
no
11 Terminal Codes 3, 5, E and H (Bus Type) with VDE, are supplied with Lock Washers,
and Terminal Code M (M6 Threaded Stud) with VDE is supplied with Lock and Flat
Washers. These breakers are only VDE Certified when the washers are used.
12 Terminal Code L: VDE Certified available up to 12A. UL Recognized & CSAAccepted
available up to 30A.
yes
13 Single pole breakers with Terminal Code P (Printed Circuit Board) are available up to 30 amps
with VDE Certification and 50 amps with UL Recognition and CSAAccepted, with Circuit
Codes A, B and C. Two pole breakers with Terminal Code P (Printed Circuit Board) are
available up to 40 amps with UL Recognition and CSAAccepted with Circuit Codes A, B and C.
14 Terminal Code Q not available with VDE certification.
11 AGENCY APPROVAL
C
D
E
I
UL Recognized & CSA Accepted
VDE Certified, UL Recognized & CSA Accepted
TUV Certified, UL Recognized & CSA Accepted
UL Recognized STD 1077, UL Recognized 1500 (ignition protected),
& CSA Accepted
15 Single pole only.
Email: sales@carlingtech.com Application Support: team2@carlingtech.com
Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com
|
7
A-Series Circuit Breaker - Handle UL489A – Ordering Scheme
A A 1 B 0 14 450 1 B 1 M T
8
9
10
Mounting/
Barriers
11
12
1
2
3
4
5
6
7
Terminal
Actuator
Color
Max. Appl. Agency
Rating
Series
Actuator
Poles
Circuit
Aux/Alarm
Switch
Frequency
& Delay
Current Rating
Approval
1 SERIES
9 ACTUATOR COLOR & LEGEND
Actuator Color
White
ON-OFF
Dual
Legend Color
Black
A
B
D
G
J
1
2
3
4
5
6
7
8
9
Black
White
1
Red
White
2 ACTUATOR
Green
White
A
S
T
Handle, one per pole
Blue
L
White
Mid-Trip Handle, one per pole
Yellow
N
Q
S
U
Black
Mid-Trip Handle, one per pole & Alarm Switch
Gray
Black
Orange
Black (short handle)
Black
10
White
2
3 POLES
1
2
3
4
One
Two
10 MOUNTING / BARRIERS
MOUNTING STYLE
Three
Four
BARRIERS
Threaded Insert, 2 per pole
1
6-32 x 0.195 inches
6-32 x 0.195 inches
ISO M3 x 5mm
no
A
2
yes
no
4 CIRCUIT
B
Series Trip (Current)
B
ISO M3 x 5mm (multipole only)
yes
Front panel Snap-In, 0.75” wide bezel
without Handleguard
2
5 AUXILIARY/ALARM SWITCH
7
S.P.S.T., 0.110 Q.C. Term.
(Gold Contacts)
S.P.S.T., 0.187 Q.C. Term.
S.P.D.T., 0.187 Q.C. Term.
5
6
no
yes
0
1
2
without Aux Switch
S.P.D.T., 0.093 Q.C. Term.
S.P.D.T., 0.110 Q.C. Term.
without Handleguard (multipole only)
Front panel Snap-In, 0.96” wide bezel
without Handleguard, 1-pole 0.96” wide;
multipole units have .105” bezel overhang on all sides
without Handleguard, 1-pole 0.96” wide;
(multipole only) .105” bezel overhang on all sides
8
9
7
8
no
yes
6 FREQUENCY & DELAY
3
3
3
11
12
14
16
DC Ultra Short
DC Short
DC Medium
DC Long
52
54
56
DC, Short,High-inrush
DC, Medium, High-inrush
DC, Long, High-inrush
11 MAXIMUM APPLICATION RATING
80 DC
M
7 CURRENT RATING (AMPERES)
12 AGENCY APPROVAL
CODE AMPERES
T
K
J
UL489A Listed
210 0.100
215 0.150
220 0.200
225 0.250
230 0.300
235 0.350
240 0.400
245 0.450
250 0.500
255 0.550
260 0.600
265 0.650
270 0.700
275 0.750
280 0.800
285 0.850
290 0.900
295 0.950
410 1.000
512 1.250
415 1.500
517 1.750
420 2.000
522 2.250
527 2.750
430 3.000
435 3.500
440 4.000
445 4.500
450 5.000
455 5.500
460 6.000
465 6.500
470 7.000
475 7.500
480 8.000
485 8.500
490 9.000
495 9.500
610 10.000
710 10.500
611 11.000
711 11.500
612 12.000
712 12.500
613 13.000
614 14.000
615 15.000
616 16.000
617 17.000
618 18.000
620 20.000
622 22.000
624 24.000
625 25.000
630 30.000
UL489A Listed, VDE Certified
UL489A Listed, TUV Certified
Notes:
1
Actuator Code:
A: Handle tie pin spacer(s) and retainers provided un-assembled with multi-pole units.
S: Handle moves to mid-position only upon electrical trip of the breaker.
T: Handle moves to mid-position and alarm switch activates only upon electrical trip of the
breaker.
2
3
4
On multi-pole breakers, one auxiliary switch is supplied, mounted in the extreme right pole.
VDE Certified to 30 amps. UL489A Listed to 50 amps.
3
635 35.000
VDE Certification available with single pole breakers only. UL489A Listing available with one
and two pole breakers.
3
640 40.000
3
645 45.000
5
6
7
Screw Terminals are recommended on ratings greater than 20 amps. Ratings over 30 amps
are only available with Terminal Codes 5, 9 G, H, M and Q.
3
650 50.000
Terminal Code 1 (Push-On) available up to 25 amps with VDE Certification and 30 amps with
UL489A Listing, but is not recommended over 20 amps.
Terminal Codes 3, 5 and H (Bus Type) with VDE, are supplied with Lock Washers, and
Terminal Code M (M6 Threaded Stud) with VDE is supplied with Lock and Flat Washers.
These breakers are only VDE Certified when the washers are used.
Single pole breakers with Terminal Code P (Printed Circuit Board) are available up to
30 amps with VDE Certification and 50 amps with UL489A Listing.
Terminal Code Q not available with VDE certification.
5
8 TERMINAL
6
1
2
3
4
5
6
Push-On 0.250 Tab (Q.C.)
Screw 8-32 with upturned lugs
Screw 8-32 (Bus Type)
Screw 10-32 with upturned lugs
Screw 10-32 (Bus Type)
Screw 8-32 with upturned lugs
& 30° bend
9
Screw 10-32 (Bus Type)
& 30° bend
8
9
7
7
B
F
Screw M5 with upturned lugs
Screw M5 with upturned lugs
& 30° bend
10 Single pole only.
G
H
M
P
Screw M5 (Bus Type) & 30° bend
Screw M5 (Bus Type)
M6 Threaded Stud
Printed Circuit Board Terminals
Push-In Stud
7
8
9
7
8
Screw 8-32 (Bus Type)
& 30° bend
Screw 10-32 with upturned lugs
& 30° bend
Q
Email: sales@carlingtech.com Application Support: team2@carlingtech.com
Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com
|
8
A-Series Circuit Breaker - Handle WORLD – Ordering Scheme
A A 3 B 0 14 450 1 A 1 P
8
9
10
Mounting/
Barriers
11
Agency
Approval
1
2
3
4
5
6
7
Terminal
Actuator
Color
Series
Actuator
Poles
Circuit
Aux/Alarm
Switch
Frequency
& Delay
Current Rating
9
1 SERIES
A
8 TERMINAL
10
1
2
3
4
5
6
Push-On 0.250 Tab (Q.C.)
B
Screw M5 with upturned lugs
Screw M4 with upturned lugs
Screw M4 (Bus Type)
Screw M5 with upturned lugs
& 30° bend
Screw 8-32 with upturned lugs
Screw 8-32 (Bus Type)
Screw 10-32 with upturned lugs
Screw 10-32 (Bus Type)
Screw 8-32 with upturned lugs
& 30° bend
C
E
F
11
11
11
1
2 ACTUATOR
A
B
S
T
Handle, one per pole
Handle, one per multipole unit
Mid-Trip Handle, one per pole
G
H
R
Screw M5 (Bus Type) & 30° bend
Screw M5 (Bus Type)
Screw M4 with upturned lugs
& 30° bend
Screw M4 (Bus Type)
& 30° bend
11
11
Mid-Trip Handle, one per pole & Alarm Switch
7
8
9
Screw 8-32 (Bus Type)
& 30° bend
Screw 10-32 with upturned lugs
& 30° bend
Screw 10-32 (Bus Type)
& 30° bend
T
3 POLES
1
2
One
Two
3
4
Three
Four
5
6
Five
Six
4 CIRCUIT
2
3
3
3,4
A
B
C
Switch Only (No Coil)
D
E
H
Shunt Trip (Current)
Shunt Trip (Voltage)
Dual Coil with Shunt Trip
Voltage Coil
9 ACTUATOR COLOR & LEGEND
Series Trip (Current)
Series Trip (Voltage)
Actuator Color
I-O
A
C
F
H
K
M
P
R
T
Dual
Legend Color
Black
White
1
2
3
4
5
6
7
8
9
Black
White
Red
White
Green
White
5
Blue
White
5 AUXILIARY / ALARM SWITCH
Yellow
Black
0
2
4
without Aux Switch
Gray
Black
S.P.D.T., 0.110 Q.C. Term.
Orange
Black
S.P.D.T., 0.093 Q.C. Term. (Gold Contacts)
Black (short handle)15
White
10 MOUNTING / BARRIERS
MOUNTING STYLE
6 FREQUENCY & DELAY
03 DC 50/60Hz, Switch Only
10 DC Instantaneous
11 DC Ultra Short
12 DC Short
BARRIERS
30 DC, 50/60Hz Instantaneous
31 DC, 50/60Hz Ultra Short
32 DC, 50/60Hz Short
Threaded Insert, 2 per pole
1
6-32 x 0.195 inches
6-32 x 0.195 inches
ISO M3 x 5mm
no
A
2
yes
no
34 DC, 50/60Hz Medium
36 DC, 50/60Hz Long
14 DC Medium
B
ISO M3 x 5mm (multipole only)
yes
7
7
7
7
7
7
16 DC Long
42 50/60Hz Short, High-inrush
Front panel Snap-In, 0.75” wide bezel
without Handleguard
20 50/60Hz Instantaneous
21 50/60Hz Ultra Short
22 50/60Hz Short
44 50/60Hz Medium, High-inrush
5
6
no
yes
46 50/60Hz Long, High-inrush
without Handleguard (multipole only)
Front panel Snap-In, 0.96” wide bezel
without Handleguard, 1-pole 0.96” wide;
multipole units have .105” bezel overhang on all sides
without Handleguard, 1-pole 0.96” wide;
(multipole only) .105” bezel overhang on all sides
52 DC, Short, High-inrush
24 50/60Hz Medium
26 50/60Hz Long
54 DC, Medium, High-inrush
7
8
no
56 DC, Long, High-inrush
yes
7 CURRENT RATING (AMPERES)
CODE AMPERES
210 0.100
215 0.150
220 0.200
225 0.250
230 0.300
235 0.350
240 0.400
245 0.450
250 0.500
255 0.550
260 0.600
265 0.650
270 0.700
275 0.750
280 0.800
285 0.850
290 0.900
295 0.950
410 1.000
512 1.250
415 1.500
517 1.750
420 2.000
522 2.250
527 2.750
430 3.000
435 3.500
440 4.000
445 4.500
450 5.000
455 5.500
460 6.000
465 6.500
470 7.000
475 7.500
480 8.000
485 8.500
490 9.000
495 9.500
610 10.000
710 10.500
611 11.000
711 11.500
612 12.000
712 12.500
613 13.000
614 14.000
615 15.000
616 16.000
617 17.000
618 18.000
620 20.000
622 22.000
624 24.000
625 25.000
630 30.000
11 AGENCY APPROVAL
P
TUV Certified, UL Recognized & CSA Accepted
Q
UL Recognized STD 1077, UL Recognized 1500 (ignition protected),
& CSA Accepted
Notes:
1
Actuator Code:
A: Handle tie pin spacer(s) and retainers provided unassembled with multi-pole units.
S: Handle moves to mid-position only upon electrical trip of the breaker. Available with circuit
codes B, C, D, E, and H.
8
T: Handle moves to mid-position and alarm switch activates only upon electrical trip of the
breaker. Available with circuit codes B & C.
Switch Only circuits, rated up to 50 amps and 6 poles, and only available when tied to a
protected pole (Circuit Code B, C, D or H.), For .01 to 30 amps, select Current Code 630.
For 35 - 50 amps, select Current Code 650.
635 35.000
8
640 40.000
2
8
645 45.000
8
650 50.000
6
OR VOLTAGE COIL (NORMAL RATED VOLTAGE)
CODE AMPERES
3
4
Available with terminal Codes 1, 2 and 3. Current Rating limited to 30 amps maximum.
Consult factory for available Dual Coil options, as special catalog number is required.
With Shunt construction, Dual Coils will trip instantaneously on line voltage. Dual coils require
30VA minimum power to trip and are rated for intermittent duty only.
On multi-pole breakers, one auxiliary switch is supplied, mounted in the extreme right pole.
Separate pole type voltage coils not rated for continuous duty. Available only with delay
codes 10, 20 & 30.
A06
6 DC
A32 32 DC
A48 48 DC
A65 65 DC
J12 12 AC
J18 18 AC
J24 24 AC
J48 48 AC
J65
65 AC
A12 12 DC
A18 18 DC
A24 24 DC
K20 120 AC
L40 240 AC
5
6
J06
6 AC
7
Available with Circuit Codes B & D only. VDE Certified to 30 amps. UL Recognized, CSA
Accepted & TUV Certified to 50 amps.
8
9
Available up to two poles with AC or DC delays.
Screw Terminals are recommended on ratings greater than 20 amps. Ratings over 30
amps are only available with Terminal Codes 5, 9, G and H.
10 Terminal Code 1: TUV Certification up to 30 amps, but not recommended over 20 amps.
11 Terminal Codes 3, 5 , 7, 9, E, G and H (Bus Type) are supplied with Lock Washers.
These breakers are only TUV Certified when the washers are used.
12 Single pole only.
Email: sales@carlingtech.com Application Support: team2@carlingtech.com
Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com
|
9
A-Series Circuit Breaker - Handle – Circuit & Terminal Diagrams
Circuit & Terminal Diagrams: in. [mm]
Notes:
1
2
3
All dimensions are in inches [millimeters].
Tolerance ±.020 [.51] unless otherwise specified.
Alarm Switch available with .110 x .020 Q.C. & Solder Lug Terminals Only.
Email: sales@carlingtech.com Application Support: team2@carlingtech.com
Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com
|
10
A-Series Circuit Breaker - Handle – Circuit & Terminal Diagrams
Circuit & Terminal Diagrams: in. [mm]
Notes:
1
2
3
All dimensions are in inches [millimeters].
Tolerance ±.020 [.51] unless otherwise specified.
Alarm Switch available with .110 x .020 QC & solder lug terminals only.
Email: sales@carlingtech.com Application Support: team2@carlingtech.com
Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com
|
11
A-Series Circuit Breaker - Handle – Dimensional Specifications
Dimensional Specifications: in. [mm]
Notes:
1
2
3
All dimensions are in inches [millimeters].
Tolerance ± 0.20 [.51] unless otherwise specified.
For agency code P = .150 [3.81].
Email: sales@carlingtech.com Application Support: team2@carlingtech.com
Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com
|
12
A-Series Circuit Breaker - Handle – Front Panel Snap-In Mounting Style 5 – Dimensional Specifications
Dimensional Specifications: in. [mm]
Notes:
1
2
3
All dimensions are in inches [millimeters].
Recommended panel thickness: .040 [1.02] to .100 [2.54].
Tolerance ±.020 [.51] unless otherwise specified.
Email: sales@carlingtech.com Application Support: team2@carlingtech.com
Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com
|
13
A-Series Circuit Breaker - Handle – Front Panel Snap-In Mounting Style 7 – Dimensional Specifications
Dimensional Specifications: in. [mm]
Notes:
1
2
3
All dimensions are in inches [millimeters].
Recommended panel thickness: .040 [1.02] to .100 [2.54].
Tolerance ±.020 [.51] unless otherwise specified.
Email: sales@carlingtech.com Application Support: team2@carlingtech.com
Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com
|
14
A-Series Circuit Breaker - Sealed Toggle UL Recognized – Ordering Scheme
A M 1 B 0 10 450 1 0 1 C
8
9
10
Mounting/
Barriers
11
Agency
Approval
1
2
3
4
5
6
7
Terminal
Actuator
Color
Series
Actuator
Poles
Circuit
Aux/Alarm
Switch
Frequency
& Delay
Current Rating
9
1 SERIES
A
8 TERMINAL
10
1
2
3
4
5
6
Push-On 0.250 Tab (Q.C.)
Screw 8-32 with upturned lugs
Screw 8-32 (Bus Type)
Screw 10-32 with upturned lugs
Screw 10-32 (Bus Type)
Screw 8-32 with upturned lugs
& 30° bend
Screw 8-32 (Bus Type)
& 30° bend
Screw 10-32 with upturned lugs
& 30° bend
E
F
Screw M4 (Bus Type)
Screw M5 with upturned lugs
& 30° bend
1
2 ACTUATOR
G
H
L
M
Q
R
Screw M5 (Bus Type) & 30° bend
Screw M5 (Bus Type)
0.250 Q.C./ Solder Lug
M6 Threaded Stud
M
Sealed Toggle, one per unit
12
3 POLES
7
8
9
Push-In Stud
1
2
3
One
Screw M4 with upturned lugs
& 30° bend
Screw M4 (Bus Type)
& 30° bend
Printed Circuit Board Terminals
Push-On 0.110 Tab (Q.C.)
Two
Three
T
Screw 10-32 (Bus Type)
& 30° bend
Screw M5 with upturned lugs
Screw M4 with upturned lugs
12
P
S
4 CIRCUIT
2
3
3
3,4
3,4
B
C
A
B
C
D
E
Switch Only (No Coil)
F
Relay Trip (Current)
Relay Trip (Voltage)
Dual Coil with Shunt Trip
Voltage Coil
Dual Coil with Relay Trip
Voltage Coil
Series Trip (Current)
Series Trip (Voltage)
Shunt Trip (Current)
Shunt Trip (Voltage)
G
H
3
3
K
9 LEGEND PLATE
No legend plate
0
5
5 AUXILIARY / ALARM SWITCH
5
7
S.P.S.T., 0.093 Q.C. Term.
(Gold Contacts)
S.P.S.T., 0.110 Q.C. Term.
(Gold Contacts)
S.P.S.T., 0.187 Q.C. Term.
S.P.D.T., 0.187 Q.C. Term.
10 MOUNTING / BARRIERS
0
1
2
4
without Aux Switch
MOUNTING STYLE
BARRIERS
no
yes
S.P.D.T., 0.093 Q.C. Term.
S.P.D.T., 0.110 Q.C. Term.
S.P.D.T., 0.093 Q.C. Term.
(Gold Contacts)
1
Standard Hex Nut
Standard Hex Nut (multipole only)
A
8
9
11 AGENCY APPROVAL
C
I
UL Recognized & CSA Accepted
UL Recognized STD 1077, UL Recognized 1500 (ignition protected),
& CSA Accepted
6 FREQUENCY & DELAY
03 DC 50/60Hz, Switch Only
10 DC Instantaneous
30 DC, 50/60Hz Instantaneous
31 DC, 50/60Hz Ultra Short
32 DC, 50/60Hz Short
11
DC Ultra Short
12 DC Short
34 DC, 50/60Hz Medium
36 DC, 50/60Hz Long
Notes:
14 DC Medium
1
Actuator Code M: Handle location as viewed from front of panel:
2 pole - right pole 3 pole - center pole
7
7
7
7
7
7
16 DC Long
42 50/60Hz Short, High-inrush
20 50/60Hz Instantaneous
21 50/60Hz Ultra Short
22 50/60Hz Short
24 50/60Hz Medium
26 50/60Hz Long
44 50/60Hz Medium, High-inrush
2
Switch Only circuits, rated up to 50 amps and 3 poles. Only available when tied to a
protected pole. For .02 to 30 amps, select Current Code 630. For 35 - 50 amps,
select Current Code 650.
Available with terminal Codes 1, 2 and 3. Current Rating limited to 30 amps maximum.
Consult factory for available Dual Coil options, as special catalog number is required. With
Shunt construction, Dual Coils will trip instantaneously on line voltage. Dual coils require
30VA minimum power to trip and are rated for intermittent duty only.
Auxiliary Switch available on Series Trip & Switch Only circuits, limited to 30 amps.
On multi-pole breakers, one auxiliary switch is supplied, mounted in the extreme right pole.
Voltage coils not rated for continuous duty. Available only with delay codes 10 and 20.
Available with Circuit Codes B & D only. VDE Certified to 30 amps. UL Recognized, CSA
Accepted & TUV Certified to 50 amps.
46 50/60Hz Long, High-inrush
52 DC, Short, High-inrush
3
4
54 DC, Medium, High-inrush
56 DC, Long, High-inrush
5
7 CURRENT RATING (AMPERES)
CODE AMPERES
6
7
020 0.020
025 0.025
030 0.030
035 0.035
040 0.040
045 0.045
050 0.050
055 0.055
060 0.060
065 0.065
070 0.070
075 0.075
080 0.080
085 0.085
090 0.090
095 0.095
210 0.100
215 0.150
220 0.200
225 0.250
230 0.300
235 0.350
240 0.400
245 0.450
250 0.500
255 0.550
260 0.600
265 0.650
270 0.700
275 0.750
280 0.800
285 0.850
290 0.900
295 0.950
410 1.000
512 1.250
415 1.500
517 1.750
420 2.000
522 2.250
425 2.500
527 2.750
430 3.000
435 3.500
440 4.000
445 4.500
450 5.000
455 5.500
460 6.000
465 6.500
470 7.000
475 7.500
480 8.000
485 8.500
490 9.000
495 9.500
610 10.000
710 10.500
611 11.000
711 11.500
612 12.000
712 12.500
613 13.000
614 14.000
615 15.000
616 16.000
617 17.000
618 18.000
620 20.000
622 22.000
624 24.000
625 25.000
630 30.000
8
9
UL Recognition and CSA Certification available on one and two pole breakers.
Screw Terminals are recommended on ratings greater than 20 amps. Ratings over
30 amps are only available with Terminal Codes 5, 9, B, F, G, H, M and Q.
10 Terminal Code 1: UL Recognition and CSA Certification up to 30 amps, but not
recommended over 20 amps.
11 Terminal Code L : available up to 30A.
12 Single pole breakers with Terminal Code P (Printed Circuit Board) are available up to
50 amps, with Circuit Codes A, B and C. Two pole breakers with Terminal Code P
(Printed Circuit Board) are available up to 40 amps with Circuit Codes A, B and C.
8
635 35.000
8
640 40.000
8
645 45.000
8
650 50.000
6
OR VOLTAGE COIL (NORMAL RATED VOLTAGE)
CODE AMPERES
A06
6 DC
A32 32 DC
A48 48 DC
A65 65 DC
J12 12 AC
J18 18 AC
J24 24 AC
J48 48 AC
J65
65 AC
A12 12 DC
A18 18 DC
A24 24 DC
K20 120 AC
L40 240 AC
J06
6 AC
Email: sales@carlingtech.com Application Support: team2@carlingtech.com
Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com
|
15
A-Series Circuit Breaker - Sealed Toggle – Dimensional Specifications
Dimensional Specifications: in. [mm]
Notes:
1
2
All dimensions are in inches [millimeters].
Tolerance ±.020 [.51] unless otherwise specified.
Email: sales@carlingtech.com Application Support: team2@carlingtech.com
Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com
|
16
A-Series Circuit Breaker - Rocker UL Recognized – Ordering Scheme
A F 1 B 0 24 630 2 3 1 D
8
9
10
Mounting/
Barriers
11
Agency
Approval
1
2
3
4
5
6
7
Terminal
Actuator
Color
Series
Actuator
Poles
Circuit
Aux/Alarm
Switch
Frequency
& Delay
Current Rating
7 CURRENT RATING (AMPERES)
CODE AMPERES
1 SERIES
A
020 0.020
025 0.025
030 0.030
035 0.035
040 0.040
045 0.045
050 0.050
055 0.055
060 0.060
065 0.065
070 0.070
075 0.075
080 0.080
085 0.085
090 0.090
095 0.095
210 0.100
215 0.150
220 0.200
225 0.250
230 0.300
235 0.350
240 0.400
245 0.450
250 0.500
255 0.550
260 0.600
265 0.650
270 0.700
275 0.750
280 0.800
285 0.850
290 0.900
295 0.950
410 1.000
512 1.250
415 1.500
517 1.750
420 2.000
522 2.250
527 2.750
430 3.000
435 3.500
440 4.000
445 4.500
450 5.000
455 5.500
460 6.000
465 6.500
470 7.000
475 7.500
480 8.000
485 8.500
490 9.000
495 9.500
610 10.000
710 10.500
611 11.000
711 11.500
612 12.000
712 12.500
613 13.000
614 14.000
615 15.000
616 16.000
617 17.000
618 18.000
620 20.000
622 22.000
624 24.000
625 25.000
630 30.000
1
2 ACTUATOR
Two Color Visi-Rocker
C
D
F
G
H
Indicate ON, vertical legend
Indicate ON, horizontal legend
Indicate OFF, vertical legend
Indicate OFF, horizontal legend
Indicate OFF, no legend
Push-To-Reset, Visi-Rocker
N
O
P
Indicate OFF, vertical legend
Indicate OFF, horizontal legend
Indicate OFF, no legend
Single color
J
K
L
Vertical legend
Horizontal legend
No legend
8
635 35.000
8
640 40.000
Push-To-Reset , Single color
8
645 45.000
R
U
V
Vertical legend
Horizontal legend
No legend
8
650 50.000
8
OR VOLTAGE COIL (NORMAL RATED VOLTAGE)
CODE AMPERES
A06
6 DC
A32 32 DC
A48 48 DC
A65 65 DC
J12 12 AC
J18 18 AC
J24 24 AC
J48 48 AC
J65
65 AC
A12 12 DC
A18 18 DC
A24 24 DC
K20 120 AC
L40 240 AC
3 POLES
One
1
2
Two
3
Three
J06
6 AC
4
4
4,5
4 CIRCUIT
F
Relay Trip (Current)
Relay Trip (Voltage)
3
11
A
B
C
D
E
Switch Only (No Coil)
G
H
8 TERMINAL
12
13
Series Trip (Current)
Series Trip (Voltage)
Shunt Trip (Current)
Shunt Trip (Voltage)
Dual Coil with Shunt Trip
Voltage Coil
1
2
3
4
5
6
Push-On 0.250 Tab (Q.C.)
Screw 8-32 with upturned lugs
Screw 8-32 (Bus Type)
Screw 10-32 with upturned lugs
Screw 10-32 (Bus Type)
Screw 8-32 with upturned lugs
& 30° bend
E
F
Screw M4 (Bus Type)
Screw M5 with upturned lugs
& 30° bend
4
4
4,5
13
13
K
Dual Coil with Relay Trip
Voltage Coil
G
H
L
M
P
Q
R
Screw M5 (Bus Type) & 30° bend
Screw M5 (Bus Type)
0.250 Q.C./ Solder Lug
M6 Threaded Stud
13
14
13
15
16
6,7
5 AUXILIARY / ALARM SWITCH
5
7
S.P.S.T., 0.093 Q.C. Term.
(Gold Contacts)
0
1
2
4
without Aux Switch
7
8
9
Screw 8-32 (Bus Type)
& 30° bend
Printed Circuit Board Terminals
Push-In Stud
S.P.D.T., 0.093 Q.C. Term.
S.P.D.T., 0.110 Q.C. Term.
S.P.D.T., 0.093 Q.C. Term.
(Gold Contacts)
S.P.S.T., 0.110 Q.C. Term.
(Gold Contacts)
Screw 10-32 with upturned lugs
& 30° bend
Screw M4 with upturned lugs
& 30° bend
8
9
S.P.S.T., 0.187 Q.C. Term.
S.P.D.T., 0.187 Q.C. Term.
17
Screw 10-32 (Bus Type)
& 30° bend
S
T
Push-On 0.110 Tab (Q.C.)
& 30° bend
B
C
Screw M5 with upturned lugs
Screw M4 with upturned lugs
Screw M4 (Bus Type)
& 30° bend
6 FREQUENCY & DELAY
03
10
11
12
14
16
20
21
22
24
26
DC 50/60Hz, Switch Only
DC Instantaneous
DC Ultra Short
30
DC, 50/60Hz Instantaneous
DC, 50/60Hz Ultra Short
DC, 50/60Hz Short
31
32
34
36
42
44
46
52
54
56
9 ACTUATOR COLOR & LEGEND
Actuator or
Marking:
ON-OFF Dual
Marking Color
Single Color Visi-Rocker
DC Short
DC, 50/60Hz Medium
DC, 50/60Hz Long
12
12
Visi-Color
White
Black
I-O
A
C
F
DC Medium
DC Long
9
9
9
9
9
9
B
D
G
J
1
2
3
4
5
6
7
8
Black
White
White
White
White
Black
Black
Black
White
n/a
50/60Hz Short, High-inrush
50/60Hz Instantaneous
50/60Hz Ultra Short
50/60Hz Short
50/60Hz Medium, High-inrush
Red
Red
50/60Hz Long, High-inrush
Green
Blue
H
K
M
P
Green
Blue
Yellow
Gray
Orange
DC, Short, High-inrush
L
50/60Hz Medium
50/60Hz Long
DC, Medium, High-inrush
Yellow
Gray
N
Q
S
DC, Long, High-inrush
Notes:
Orange
R
1
2
Push-To-Reset actuators have OFF portion of rocker shrouded.
Multi-pole breakers have all breakers identical except when specifying Auxiliary switch and/or mixed
poles, and have one rocker per breaker.
Switch Only circuits, rated up to 50 amps & 3 poles, are available only when tied to a protected pole
(Circuit Code B, C, D or H.), For .02 to 30 amps, select Current Code 630.
For 35 - 50 amps, select Current Code 650.
Available with terminal Codes 1, 2 and 3. Current Rating limited to 30 amps maximum.
Consult factory for Dual Coil options, as special catalog number is required.
With Shunt construction, Dual Coils will trip instantaneously on line voltage. Dual coils require 30VA
minimum power to trip and are rated for intermittent duty only.
Auxiliary Switch breakers with Series Trip & Switch Only circuits: ≤ 30A, are supplied with
standard half shells. 30-50A are supplied with extended boat (B-Style) half shells.
On multi-pole breakers, one auxiliary switch is supplied, mounted in the extreme right pole.
Separate pole type voltage coils not rated for continuous duty. Available only with delay codes 10 & 20.
Available with Circuit Codes B & D only. VDE Certified to 30 amps. UL Recognized, CSA Accepted
& TUV Certified to 50 amps.
10 Series Trip current ratings: VDE Certification available with single pole breakers with DC Delay only.
UL Recognition & CSAAccepted available in one and two pole breakers.
11 Screw Terminals are recommended on ratings greater than 20 amps. Ratings over 30 amps are only
available with Terminal Codes 5, 9, G, H, M and Q.
12 Terminal Code 1: VDE Certification up to 25 amps and UL Recognition and CSAAccepted up to 30
amps, but not recommended over 20 amps.
20
3
10 MOUNTING / BARRIERS
STANDARD ROCKER BEZEL
Threaded Insert, 2 per pole
6-32 x 0.195 inches
BARRIERS
4
5
1
no
A
2
6-32 X 0.195 inches (multi-pole units only)
ISO M3 x 5mm
yes
no
6
B
ISO M3 x 5mm (multi-pole units only)
ROCKERGUARD & PUSH-TO-RESET BEZEL
Threaded Insert, 2 per pole
6-32 x 0.195 inches
yes
7
8
9
3
no
C
4
D
6-32 x 0.195 inches (multi-pole units only)
ISO M3 x 5mm
yes
no
ISO M3 x 5mm (multi-pole units only)
yes
FRONT PANEL SNAP-IN BRACKET, 0.744” [18.90mm] wide bezel
8
H
without Rockerguard (single pole units only)
with Rockerguard (single pole units only)
no
no
FRONT PANEL SNAP-IN BRACKET, 0.96” [24.48mm] wide bezel
13 Terminal Codes 3, 5 E & H (Bus Type) with VDE, are supplied with Lock Washers; Terminal Code M
(M6 Threaded Stud) with VDE is supplied with Lock and Flat Washers. These breakers are only VDE
Certified when the washers are used.
14 VDE Cert. available up to 12 amps. UL Rec. & CSAAccepted available up to 30 amps.
15 Single pole breakers with Terminal Code P (Printed Circuit Board) are available up to 30 amps with
VDE Certification and 50 amps with UL Recognition and CSAAccepted, with Circuit Codes A, B & C.
Two pole breakers with Terminal Code P (Printed Circuit Board) are available up to 40 amps with
UL Recognition and CSA Certification with Circuit Codes A, B and C.
9
J
without Rockerguard (single pole units only)
with Rockerguard (single pole units only)
no
no
11 AGENCY APPROVAL
C
D
E
I
UL Recognized & CSA Accepted
16 Terminal Code Q not available with VDE.
VDE Certified, UL Recognized & CSA Accepted
TUV Certified, UL Recognized & CSA Accepted
UL Recognized STD 1077, UL Recognized 1500 (ignition protected),
& CSA Accepted
17 Terminal Code S used on voltage coil circuit constructions only.
18 Color shown is visi and legend with remainder of rocker black.
19 Dual = ON-OFF/I-O legend with actuator. None = no legend on actuator
20 Legend on Push-to-reset bezel/shroud is white with single color actuator codes R, & U. Legend on
Push-to-reset bezel/shroud matches Visi-color of rocker with actuator codes N & O.
Rockerguard available with actuator codes C through L.
Email: sales@carlingtech.com Application Support: team2@carlingtech.com
Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com
|
17
A-Series Circuit Breaker - Rocker UL489A – Ordering Scheme
A F 1 B 0 14 450 1 3 1 M T
8
9
10
Mounting/
Barriers
11
12
1
2
3
4
5
6
7
Terminal
Actuator
Color
Max. Appl. Agency
Rating Approval
Series
Actuator
Poles
Circuit
Aux/Alarm
Switch
Frequency
& Delay
Current Rating
5
1 SERIES
8 TERMINAL
6
7
7
A
1
2
3
4
5
6
Push-On 0.250 Tab (Q.C.)
Screw 8-32 with upturned lugs
Screw 8-32 (Bus Type)
Screw 10-32 with upturned lugs
Screw 10-32 (Bus Type)
Screw 8-32 with upturned lugs
& 30° bend
Screw 8-32 (Bus Type)
& 30° bend
Screw 10-32 with upturned lugs
& 30° bend
9
Screw 10-32 (Bus Type)
& 30° bend
B
F
Screw M5 with upturned lugs
Screw M5 with upturned lugs
& 30° bend
1
2 ACTUATOR
Two Color Visi-Rocker
Push-To-Reset, Visi-Rocker
C
D
F
Indicate ON, vertical legend
Indicate ON, horizontal legend
Indicate OFF, vertical legend
Indicate OFF, horizontal legend
N
O
Indicate OFF, vertical legend
Indicate OFF, horizontal legend
G
H
M
P
Screw M5 (Bus Type) & 30° bend
Screw M5 (Bus Type)
M6 Threaded Stud
Printed Circuit Board Terminals
Push-In Stud
7
8
9
7
8
G
Single color
J
K
Push-To-Reset , Single color
Q
Vertical legend
Horizontal legend
R
U
Vertical legend
Horizontal legend
9 ACTUATOR COLOR & LEGEND
Actuator or
Marking:
Marking Color
10
10
Visi-Color
White
Black
ON-OFF
Dual
Single Color Visi-Rocker
B
D
G
J
1
2
3
4
5
6
7
8
Black
White
White
White
White
Black
Black
Black
White
n/a
Red
Green
Blue
Yellow
Gray
Orange
Red
Green
Blue
Yellow
Gray
Orange
L
N
Q
S
11
10 MOUNTING / BARRIERS
STANDARD ROCKER BEZEL
Threaded Insert, 2 per pole
6-32 x 0.195 inches
6-32 X 0.195 inches (multi-pole units only)
ISO M3 x 5mm
ISO M3 x 5mm (multi-pole units only)
ROCKERGUARD & PUSH-TO-RESET BEZEL
Threaded Insert, 2 per pole
6-32 x 0.195 inches
BARRIERS
1
no
A
2
yes
no
2
3 POLES
1
2
3
One
B
yes
Two
Three
3
no
C
4
6-32 x 0.195 inches (multi-pole units only)
ISO M3 x 5mm
yes
no
4 CIRCUIT
B
Series Trip (Current)
D
ISO M3 x 5mm (multi-pole units only)
yes
FRONT PANEL SNAP-IN BRACKET, 0.744” [18.90mm] wide bezel
8
H
without Rockerguard (single pole units only)
with Rockerguard (single pole units only)
no
no
2
5 AUXILIARY / ALARM SWITCH
7
S.P.S.T., 0.110 Q.C. Term.
(Gold Contacts)
S.P.S.T., 0.187 Q.C. Term.
S.P.D.T., 0.187 Q.C. Term.
0
1
2
without Aux Switch
FRONT PANEL SNAP-IN BRACKET, 0.96” [24.48mm] wide bezel
without Rockerguard (single pole units only)
with Rockerguard (single pole units only)
S.P.D.T., 0.093 Q.C. Term.
S.P.D.T., 0.110 Q.C. Term.
8
9
9
J
no
no
6 FREQUENCY & DELAY
11 MAXIMUM APPLICATION RATING
80 DC
11
12
14
16
DC Ultra Short
DC Short
52
54
56
DC, Short, High-inrush
DC, Medium, High-inrush
DC, Long, High-inrush
M
DC Medium
DC Long
12 AGENCY APPROVAL
T
K
J
UL489A Listed
UL489A Listed, VDE Certified
UL489A Listed, TUV Certified
7 CURRENT RATING (AMPERES)
CODE AMPERES
210 0.100
215 0.150
220 0.200
225 0.250
230 0.300
235 0.350
240 0.400
245 0.450
250 0.500
255 0.550
260 0.600
265 0.650
270 0.700
275 0.750
280 0.800
285 0.850
290 0.900
295 0.950
410 1.000
512 1.250
415 1.500
517 1.750
420 2.000
522 2.250
527 2.750
430 3.000
435 3.500
440 4.000
445 4.500
450 5.000
455 5.500
460 6.000
465 6.500
470 7.000
475 7.500
480 8.000
485 8.500
490 9.000
495 9.500
610 10.000
710 10.500
611 11.000
711 11.500
612 12.000
712 12.500
613 13.000
614 14.000
615 15.000
616 16.000
617 17.000
618 18.000
620 20.000
622 22.000
624 24.000
625 25.000
630 30.000
Notes:
1
2
Push-To-Reset actuators have OFF portion of rocker shrouded.
Multi-pole breakers have all breakers identical except when specifying Auxiliary switch and/or
mixed poles, and have one rocker per breaker.
3
4
5
6
7
Auxiliary Switch breakers with Series Trip circuits: ≤ 30A, are supplied with standard half shells.
30-50A are supplied with extended boat (B-Style) half shells.
VDE Certification available with single pole breakers only. UL489A Listing available with one
and two pole breakers.
Screw Terminals are recommended on ratings greater than 20 amps. Ratings over 30 amps
are only available with Terminal Codes 5, 9, G, H, M and Q.
Terminal Code 1 (Push-On) available up to 25 amps with TUV or VDE Certification and 30
amps with UL489A Listing, but is not recommended over 20 amps.
4
635 35.000
Terminal Codes 3, 5 and H (Bus Type) with TUV or VDE, are supplied with Lock Washers, and
Terminal Code M (M6 Threaded Stud) with VDE is supplied with Lock and Flat Washers.
These breakers are only TUV or VDE Certified when the washers are used.
Single pole breakers with Terminal Code P (Printed Circuit Board) are available up to 30 amps
with VDE Certification and 50 amps with UL489A Listing.
4
640 40.000
4
645 45.000
4
8
9
650 50.000
Terminal Code Q not available with VDE certification.
10 Color shown is Visi and Legend with remainder of rocker black. Dual = ON-OFF/I-O legend.
11 Legend on Push-to-reset bezel/shroud is white with single color actuator codes R & U.
Legend on Push-To-Reset bezel/shroud matches Visi-Color of rocker with actuator codes
N & O. Rockerguard available with actuator codes C through K
Email: sales@carlingtech.com Application Support: team2@carlingtech.com
Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com
|
18
A-Series Circuit Breaker - Rocker – Circuit & Terminal Diagrams
Circuit & Terminal Diagrams: in. [mm]
Notes:
1
2
3
4
All dimensions are in inches [millimeters].
Tolerance ±.020 [.51] unless otherwise specified.
Schematic shown represents current trip circuit.
Circuits shown for >30 amps / VDE.
Email: sales@carlingtech.com Application Support: team2@carlingtech.com
Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com
|
19
A-Series Circuit Breaker - Rocker - Dimensional Specifications
Dimensional Specifications: in. [mm]
Notes:
1
Dimensions apply to all variations shown. Notice that circuit breaker line & load
terminal orientation on indicate OFF is opposite of indicate ON.
For pole orientation with horizontal legend, rotate front view clockwise 90°.
All dimensions are in inches [millimeters].
2
3
4
Tolerance ± 0.20 [.51] unless otherwise specified.
Email: sales@carlingtech.com Application Support: team2@carlingtech.com
Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com
|
20
A-Series Circuit Breaker - Rocker Snap-In Bracket - Dimensional Specifications
Dimensional Specifications: in. [mm]
Notes:
1
Dimensions apply to all variations shown. Notice that circuit breaker line
& load terminal
2
For pole orientation with horizontal legend, rotate front view clockwise 90°.
Orientation on indicate “OFF” is opposite of indicate “ON”
Recommended panel thickness: .04 0 [1.02] to .100 [2.54]
All dimensions are in Inches [millimeters].
3
4
5
Tolerance ±.020 [.51] unless otherwise specified.
Email: sales@carlingtech.com Application Support: team2@carlingtech.com
Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com
|
21
A-Series Circuit Breaker - PC Terminal Diagrams
PC Terminal Diagrams: in. [mm]
Notes:
1
2
3
Drawing illustrates A-Series with VDE certification.
All dimensions are in inches [millimeters].
Tolerance ± 0.20 [.51] unless otherwise specified
Email: sales@carlingtech.com Application Support: team2@carlingtech.com
Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com
|
22
A-Series Circuit Breaker - Flat Rocker UL Recognized – Ordering Scheme
A 1 1 B 0 24 630 2 3 1 E
8
9
10
Mounting/
Barriers
11
Agency
Approval
1
2
3
4
5
6
7
Terminal
Actuator
Color
Series
Actuator
Poles
Circuit
Aux/Alarm
Switch
Frequency
& Delay
Current Rating
11
8 TERMINAL
1 SERIES
A
12
13
1
2
3
4
5
6
Push-On 0.250 Tab (Q.C.)
Screw 8-32 with upturned lugs
Screw 8-32 (Bus Type)
Screw 10-32 with upturned lugs
Screw 10-32 (Bus Type)
Screw 8-32 with upturned lugs
& 30° bend
E
F
Screw M4 (Bus Type)
Screw M5 with upturned lugs
& 30° bend
13
13
1
2 ACTUATOR
Two Color Visi-Rocker
G
H
L
M
P
Q
R
Screw M5 (Bus Type) & 30° bend
Screw M5 (Bus Type)
0.250 Q.C./ Solder Lug
M6 Threaded Stud
13
14
13
15
1
2
Indicate OFF, vertical legend
Indicate OFF, horizontal legend
Single color
7
8
9
Screw 8-32 (Bus Type)
& 30° bend
Printed Circuit Board Terminals
Push-In Stud
3
4
Vertical legend
Horizontal legend
Screw 10-32 with upturned lugs
& 30° bend
Screw M4 with upturned lugs
& 30° bend
Push-To-Reset, Visi-Rocker
16
5
6
Indicate OFF, vertical legend
Indicate OFF, horizontal legend
Screw 10-32 (Bus Type)
& 30° bend
S
T
Push-On 0.110 Tab (Q.C.)
& 30° bend
Push-To-Reset , Single color
B
C
Screw M5 with upturned lugs
Screw M4 with upturned lugs
Screw M4 (Bus Type)
& 30° bend
7
8
Vertical legend
Horizontal legend
9 ACTUATOR COLOR & LEGEND
Actuator or
Marking:
Marking Color
2
17
17
3 POLES
One
Visi-Color
White
Black
ON-OFF
Dual
Single Color Visi-Rocker
1
2
Two
3
Three
B
D
G
J
1
2
3
4
5
6
7
8
Black
White
White
White
White
Black
Black
Black
White
n/a
Red
Red
4
4
4,5
4 CIRCUIT
F
Relay Trip (Current)
Relay Trip (Voltage)
Green
Blue
Green
Blue
3
A
B
C
D
E
Switch Only (No Coil)
G
H
L
Series Trip (Current)
Series Trip (Voltage)
Shunt Trip (Current)
Shunt Trip (Voltage)
Dual Coil with Shunt Trip
Voltage Coil
Yellow
Gray
N
Q
S
Yellow
Gray
Orange
4
4
4,5
K
Dual Coil with Relay Trip
Voltage Coil
Orange
18
10 MOUNTING / BARRIERS
6,7
5 AUXILIARY / ALARM SWITCH
5
7
S.P.S.T., 0.093 Q.C. Term.
(Gold Contacts)
STANDARD ROCKER BEZEL
Threaded Insert, 2 per pole
FLAT ROCKER ACTUATOR
6-32 x 0.195 inches
6-32 X 0.195 inches (multi-pole units only)
ISO M3 x 5mm
BARRIERS
0
1
2
4
without Aux Switch
S.P.D.T., 0.093 Q.C. Term.
S.P.D.T., 0.110 Q.C. Term.
S.P.D.T., 0.093 Q.C. Term.
(Gold Contacts)
S.P.S.T., 0.110 Q.C. Term.
(Gold Contacts)
1
no
8
9
S.P.S.T., 0.187 Q.C. Term.
S.P.D.T., 0.187 Q.C. Term.
A
2
yes
no
B
ISO M3 x 5mm (multi-pole units only)
RECESSED OFF SIDE ROCKER ACTUATOR
6-32 x 0.195 inches
yes
19
6 FREQUENCY & DELAY
5
E
6
F
no
03 DC 50/60Hz, Switch Only
30 DC, 50/60Hz Instantaneous
31 DC, 50/60Hz Ultra Short
32 DC, 50/60Hz Short
6-32 x 0.195 inches (multi-pole units only)
ISO M3 x 5mm
yes
no
6
10 DC Instantaneous
11
DC Ultra Short
ISO M3 x 5mm (multi-pole units only)
yes
12 DC Short
14 DC Medium
16 DC Long
34 DC, 50/60Hz Medium
36 DC, 50/60Hz Long
PUSH-TO-RESET BEZEL,Threaded Insert, 2 per pole
3
6-32 x 0.195 inches
no
9
9
9
9
42 50/60Hz Short, High-inrush
C
4
6-32 x 0.195 inches (multi-pole units only)
ISO M3 x 5mm
ISO M3 x 5mm (multi-pole units only)
yes
no
6
20 50/60Hz Instantaneous
44 50/60Hz Medium, High-inrush
21 50/60Hz Ultra Short
22 50/60Hz Short
24 50/60Hz Medium
26 50/60Hz Long
46 50/60Hz Long, High-inrush
D
yes
52 DC, Short, High-inrush
9
54 DC, Medium, High-inrush
56 DC, Long, High-inrush
11 AGENCY APPROVAL
C
E
I
UL Recognized & CSA Accepted
TUV Certified, UL Recognized & CSA Accepted
7 CURRENT RATING (AMPERES)
UL Recognized STD 1077, UL Recognized 1500 (ignition protected),
& CSA Accepted
CODE AMPERES
020 0.020
025 0.025
030 0.030
035 0.035
040 0.040
045 0.045
050 0.050
055 0.055
060 0.060
065 0.065
070 0.070
075 0.075
080 0.080
085 0.085
090 0.090
095 0.095
210 0.100
215 0.150
220 0.200
225 0.250
230 0.300
235 0.350
240 0.400
245 0.450
250 0.500
255 0.550
260 0.600
265 0.650
270 0.700
275 0.750
280 0.800
285 0.850
290 0.900
295 0.950
410 1.000
512 1.250
415 1.500
517 1.750
420 2.000
522 2.250
527 2.750
430 3.000
435 3.500
440 4.000
445 4.500
450 5.000
455 5.500
460 6.000
465 6.500
470 7.000
475 7.500
480 8.000
485 8.500
490 9.000
495 9.500
610 10.000
710 10.500
611 11.000
711 11.500
612 12.000
712 12.500
613 13.000
614 14.000
615 15.000
616 16.000
617 17.000
618 18.000
620 20.000
622 22.000
624 24.000
625 25.000
630 30.000
Notes:
1
2
Push-To-Reset actuators have OFF portion of rocker shrouded.
Multi-pole breakers have all breakers identical except when specifying Auxiliary switch and/or
mixed poles, and have one rocker per breaker.
3
Switch Only circuits, rated up to 50 amps & 3 poles. Only available when tied to a protected
pole. For .02 to 30 amps, select Current Code 630. For 35 - 50 amps, select Current Code 650.
Available with terminal Codes 1, 2 and 3. Current Rating limited to 30 amps maximum.
Consult factory for Dual Coil options, as special catalog number is required. With Shunt
construction, Dual Coils will trip instantaneously on line voltage. Dual coils require 30VA
minimum power to trip and are rated for intermittent duty only.
Auxiliary Switch breakers with Series Trip & Switch Only circuits: ≤ 30A, are supplied with
standard half shells. 30-50A are supplied with extended boat (B-Style) half shells.
On multi-pole breakers, one auxiliary switch is supplied, mounted in the extreme right pole.
Separate pole type voltage coils not rated for continuous duty. Available only with delay codes 10 & 20.
Available with Circuit Codes B & D only. UL Recognized, CSAAccepted & TUV Certified to 50 amps.
4
5
6
7
8
9
8
635 35.000
10 UL Recognition, CSAAcceptance & TUV Certification available in one and two pole breakers.
11 Screw Terminals are recommended on ratings greater than 20 amps. Ratings over 30 amps are
only available with Terminal Codes 5, 9, G, H, M and Q.
12 Terminal Code 1: Available up to 30 amps, but not recommended over 20 amps.
13 Terminal Codes 3, 5 E & H (Bus Type) with TUV, are supplied with Lock Washers; Terminal
Code M (M6 Threaded Stud) with TUV is supplied with Lock and Flat Washers. These breakers
are only TUV Certified when the washers are used.
8
640 40.000
8
645 45.000
8
650 50.000
8
OR VOLTAGE COIL (NORMAL RATED VOLTAGE)
CODE AMPERES
14 TUV Cert. available up to 12 amps. UL Rec. & CSAAccepted available up to 30 amps.
15 Single pole breakers with Terminal Code P (Printed Circuit Board) are available up to 50 amps
with UL Recognition, CSAAccepted & TUV Certification, with Circuit Codes A, B and C. Two
pole breakers with Terminal Code P (Printed Circuit Board) are available up to 40 amps with UL
Recognition and CSA Accepted with Circuit Codes A, B and C.
A06
6 DC
A32 32 DC
A48 48 DC
A65 65 DC
J12 12 AC
J18 18 AC
J24 24 AC
J48 48 AC
J65
65 AC
A12 12 DC
A18 18 DC
A24 24 DC
K20 120 AC
L40 240 AC
J06
6 AC
16 Terminal Code S used on voltage coil circuit constructions only.
17 Color shown is visi and legend with remainder of rocker black, Dual = ON-OFF/I-O legend.
18 Legend on Push-to-reset bezel/shroud is white with single color actuator codes 7 & 8. Legend
on Push-To-Reset bezel/shroud matches Visi-Color of rocker with actuator codes 5 & 6.
19 Recessed “off-side” available with actuator codes 1, 2, 3 & 4. Legends on rocker are available
in ink stamping only.
Email: sales@carlingtech.com Application Support: team2@carlingtech.com
Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com
|
23
A-Series Circuit Breaker - Flat Rocker UL 489A – Ordering Scheme
A 1 1 B 0 14 630 2 3 1 M T
8
9
10
Mounting/
Barriers
11
12
1
2
3
4
5
6
7
Terminal
Actuator
Color
Max. Appl. Agency
Rating Approval
Series
Actuator
Poles
Circuit
Aux/Alarm
Switch
Frequency
& Delay
Current Rating
5
8 TERMINAL
1 SERIES
6
7
7
1
2
3
4
5
6
Push-On 0.250 Tab (Q.C.)
Screw 8-32 with upturned lugs
Screw 8-32 (Bus Type)
Screw 10-32 with upturned lugs
Screw 10-32 (Bus Type)
Screw 8-32 with upturned lugs
& 30° bend
Screw 8-32 (Bus Type)
& 30° bend
Screw 10-32 with upturned lugs
& 30° bend
9
Screw 10-32 (Bus Type)
& 30° bend
A
B
F
Screw M5 with upturned lugs
Screw M5 with upturned lugs
& 30° bend
1
2 ACTUATOR
Two Color Visi-Rocker
1
2
Indicate OFF, vertical legend
Indicate OFF, horizontal legend
G
H
M
P
Screw M5 (Bus Type) & 30° bend
Screw M5 (Bus Type)
M6 Threaded Stud
Printed Circuit Board Terminals
Push-In Stud
Single color
7
8
9
7
8
3
4
Vertical legend
Horizontal legend
Q
Push-To-Reset, Visi-Rocker
5
6
Indicate OFF, vertical legend
Indicate OFF, horizontal legend
Push-To-Reset , Single color
9 ACTUATOR COLOR & LEGEND
7
8
Vertical legend
Horizontal legend
Actuator or
Marking:
Marking Color
11
11
Visi-Color
White
Black
ON-OFF
Dual
Single Color Visi-Rocker
B
D
G
J
1
2
3
4
5
6
7
8
Black
White
White
White
White
Black
Black
Black
White
n/a
2
Red
Red
3 POLES
One
Green
Blue
Green
Blue
1
2
Two
3
Three
L
Yellow
Gray
N
Q
S
Yellow
Gray
Orange
4 CIRCUIT
Series Trip (Current)
Orange
B
3
12
5 AUXILIARY / ALARM SWITCH
7
S.P.S.T., 0.110 Q.C. Term.
(Gold Contacts)
10 MOUNTING / BARRIERS
0
1
2
without Aux Switch
STANDARD ROCKER BEZEL
Threaded Insert, 2 per pole
FLAT ROCKER ACTUATOR
6-32 x 0.195 inches
6-32 X 0.195 inches (multi-pole units only)
ISO M3 x 5mm
BARRIERS
S.P.D.T., 0.093 Q.C. Term.
S.P.D.T., 0.110 Q.C. Term.
8
9
S.P.S.T., 0.187 Q.C. Term.
S.P.D.T., 0.187 Q.C. Term.
1
no
A
2
yes
no
6 FREQUENCY & DELAY
B
ISO M3 x 5mm (multi-pole units only)
RECESSED OFF SIDE ROCKER ACTUATOR
6-32 x 0.195 inches
yes
11
12
14
16
DC Ultra Short
DC Short
DC Medium
DC Long
52
54
56
DC, Short, High-inrush
DC, Medium, High-inrush
DC, Long, High-inrush
5
E
6
F
no
6-32 x 0.195 inches (multi-pole units only)
ISO M3 x 5mm
yes
no
ISO M3 x 5mm (multi-pole units only)
yes
PUSH-TO-RESET BEZEL,Threaded Insert, 2 per pole
7 CURRENT RATING (AMPERES)
3
6-32 x 0.195 inches
no
CODE AMPERES
C
4
6-32 x 0.195 inches (multi-pole units only)
ISO M3 x 5mm
ISO M3 x 5mm (multi-pole units only)
yes
no
020 0.020
025 0.025
030 0.030
035 0.035
040 0.040
045 0.045
050 0.050
055 0.055
060 0.060
065 0.065
070 0.070
075 0.075
080 0.080
085 0.085
090 0.090
095 0.095
210 0.100
215 0.150
220 0.200
225 0.250
230 0.300
235 0.350
240 0.400
245 0.450
250 0.500
255 0.550
260 0.600
265 0.650
270 0.700
275 0.750
280 0.800
285 0.850
290 0.900
295 0.950
410 1.000
512 1.250
415 1.500
517 1.750
420 2.000
522 2.250
527 2.750
430 3.000
435 3.500
440 4.000
445 4.500
450 5.000
455 5.500
460 6.000
465 6.500
470 7.000
475 7.500
480 8.000
485 8.500
490 9.000
495 9.500
610 10.000
710 10.500
611 11.000
711 11.500
612 12.000
712 12.500
613 13.000
614 14.000
615 15.000
616 16.000
617 17.000
618 18.000
620 20.000
622 22.000
624 24.000
625 25.000
630 30.000
D
yes
11 MAXIMUM APPLICATION RATING
80 DC
M
12 AGENCY APPROVAL
T
J
UL489A Listed
UL489A Listed, TUV Certified
Notes:
1
2
Push-To-Reset actuators have OFF portion of rocker shrouded.
Multi-pole breakers have all breakers identical except when specifying Auxiliary switch and/or
mixed poles, and have one rocker per breaker.
Auxiliary Switch breakers with Series Trip circuits: ≤ 30A, are supplied with standard half
shells. 30-50A are supplied with extended boat (B-Style) half shells.
VDE Certification available with single pole breakers only. UL489A Listing available with one
and two pole breakers.
Screw Terminals are recommended on ratings greater than 20 amps. Ratings over 30 amps
are only available with Terminal Codes 5, 9, G, H, M and Q.
Terminal Code 1 (Push-On) available up to 25 amps with TUV or VDE Certification and 30
amps with UL489A Listing, but is not recommended over 20 amps.
4
635 35.000
4
640 40.000
4
645 45.000
3
4
5
6
7
4
650 50.000
Terminal Codes 3, 5 and H (Bus Type) with TUV or VDE, are supplied with Lock Washers,
and Terminal Code M (M6 Threaded Stud) with VDE is supplied with Lock and Flat Washers.
These breakers are only TUV or VDE Certified when the washers are used.
Single pole breakers with Terminal Code P (Printed Circuit Board) are available up to 30
amps with VDE Certification and 50 amps with UL489A Listing.
8
9
Terminal Code Q not available with VDE certification.
10 Color shown is Visi and Legend with remainder of rocker black. Dual = ON-OFF/I-O legend.
11 Legend on Push-to-reset bezel/shroud is white with single color actuator codes R & U.
12 Legend on Push-To-Reset bezel/shroud matches Visi-Color of rocker with actuator
codes N & O. Rockerguard available with actuator codes C through K
Email: sales@carlingtech.com Application Support: team2@carlingtech.com
Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com
|
24
A-Series Circuit Breaker - Flat Rocker - Dimensional Specifications
Dimensional Specifications: in. [mm]
Notes:
1
2
3
All dimensions are in inches [millimeters].
For pole orientation with horizontal legend, rotate front view clockwise 90°.
Tolerance ± 0.20 [.51] unless otherwise specified.
Email: sales@carlingtech.com Application Support: team2@carlingtech.com
Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com
|
25
A-Series Circuit Breaker - Recessed Paddle – Ordering Scheme
A Y 2 B 0 24 620 4 2 1 C C
8
9
10
Mounting/
Barriers
11
12
1
2
3
4
5
6
7
Terminal
Actuator
Color
Max. Appl. Agency
Rating Approval
Series
Actuator
Poles
Circuit
Auxiliary
Switch
Frequency
& Delay
Current Rating
8 TERMINAL
1 SERIES
A
1
2
3
4
5
6
Push-On 0.250 Tab (Q.C.)
Screw 8-32 with upturned lugs
Screw 8-32 (Bus Type)
Screw 10-32 with upturned lugs
Screw 10-32 (Bus Type)
Screw 8-32 with upturned lugs
& 30° bend
C
E
F
Screw, M4 with upturned lugs
Screw, M4 (Bus Type)
Screw M5 with upturned lugs
& 30° bend
Screw M5 (Bus Type) & 30° bend
Screw M5 (Bus Type)
0.250 Q.C./Solder Lug
M6 Threaded Stud
Printed Circuit Board Terminals
Push-In Stud
Screw, M4 with upturned lugs
& 30° Bend
1
2 ACTUATOR
Y
Single Color Recessed Paddle Actuator with Vertical Legends
G
H
L
M
P
Q
R
2
3 POLES
One
7
8
9
B
Screw 8-32 (Bus Type)
& 30° bend
Screw 10-32 with upturned lugs
& 30° bend
Screw 10-32 (Bus Type)
& 30° bend
Screw M5 with upturned lugs
1
2
Two
3
Three
4 CIRCUIT
A
B
C
D
E
Switch-Only (No Coil)
F
Relay Trip (Current)
Relay Trip (Voltage)
Series Trip (Current)
Series Trip (Voltage)
Shunt Trip (Current)
Shunt Trip (Voltage)
G
H
K
S
T
Screw, M5 with upturned lugs
Screw, M4 with upturned lugs
Dual Coil with Shunt Trip Voltage Coil
Dual Coil with Shunt Trip Current Coil
5
9 ACTUATOR COLOR & LEGEND
Actuator Color
White
I-O
A
C
F
H
K
M
P
ON-OFF
Dual
Legend Color
Black
5 AUXILIARY SWITCH
B
D
G
J
1
2
3
4
5
6
7
8
0
1
2
3
4
5
6
7
8
9
without Aux Switch
Black
White
S.P.D.T. with 0.093 Q.C. Terminals
Red
White
S.P.D.T. with 0.110 Q.C. Terminals
Green
Blue
Yellow
Gray
White
S.P.D.T. with 0.139 Solder Lug Terminals
S.P.D.T. with 0.093 Q.C. Terminals (Gold Contacts)
S.P.D.T. with 0.093 Q.C. Terminals (Gold Contacts)
S.P.S.T.-N.O. with 0.139 Solder Lug Terminals
S.P.S.T.-N.O. with 0.110 Q.C. Terminals (Gold Contacts)
S.P.S.T.-N.O. with 0.187 Q.C. Terminals
S.P.D.T. with 0.187 Q.C. Terminals
L
White
N
Q
S
Black
Black
Orange
R
Black
10 MOUNTING / BARRIERS
BARRIERS
1
6-32 x 0.195 inches
no
A
2
B
6-32 X 0.195 inches (multi-pole units only)
ISO M3 x 5mm
yes
no
3
6 FREQUENCY & DELAY
22 50/60 Hz Short
3
DC, 50/60 Hz Switch Only
24 50/60 Hz Medium
ISO M3 x 5mm (multi-pole units only)
yes
10 DC Instantaneous
11 DC Ultra Short
12 DC Short
26 50/60 Hz Long
42 50/60 Hz Short High-inrush
44 50/60 Hz Medium High-inrush
46 50/60 Hz Long High-inrush
52 DC, Short, High-inrush
54 DC, Medium, High-inrush
56 DC, Long, High-inrush
6
11 MAXIMUM APPLICATION RATING
14 DC Medium
A
C
K
M
65 VDC
16 DC Long
120/240 VAC (Available only on 2 or 3-Pole units)
20 50/60 Hz Instantaneous
21 50/60 Hz Ultra Short
120 VAC
80 DC
4
7 CURRENT RATING (AMPERES)
7
12 AGENCY APPROVAL
CODE AMPERES
A
C
T
Without Approvals
220 0.200
225 0.250
230 0.300
235 0.350
240 0.400
245 0.450
250 0.500
255 0.550
260 0.600
265 0.650
270 0.700
275 0.750
280 0.800
285 0.850
290 0.900
295 0.950
410 1.000
512 1.250
415 1.500
517 1.750
420 2.000
522 2.250
425 2.500
527 2.750
430 3.000
435 3.500
440 4.000
445 4.500
450 5.000
455 5.500
460 6.000
465 6.500
470 7.000
475 7.500
480 8.000
485 8.500
490 9.000
495 9.500
610 10.000
710 10.500
611 11.000
711 11.500
612 12.000
712 12.500
613 13.000
614 14.000
615 15.000
616 16.000
617 17.000
618 18.000
620 20.000
622 22.000
624 24.000
625 25.000
630 30.000
635 35.000
640 40.000
645 45.000
650 50.000
UL Recognized and CSA Accepted
UL 489A
Notes:
1
All standard catalog numbers are supplied with Vertical Legends. For Horizontal or other
non-standard legends, choose “X” and order as a special catalog number.
For rating (T) 2 & 3 Pole not available.
Frequency and Time Delay ratings of (03, 20, 21, 22, 24, 26, 42, 44, 46) not
available with approval T.
Voltage Coil Ratings starting with (J, K, or L) not available with approval T.
“OFF and/or “O” Legends are on Bracket and are only visible when the Paddle Actuator is in
the off position.
Maximum Application Ratings (C & K) not available with approval T.
Not all approvals are available in all constructions. Consult factory for details.
2
3
4
5
6
7
OR VOLTAGE COIL (NORMAL RATED VOLTAGE)
CODE AMPERES
A06
6 DC
A32 32 DC
A48 48 DC
A65 65 DC
J12 12 AC
J18 18 AC
J24 24 AC
J48 48 AC
J65
65 AC
A12 12 DC
A18 18 DC
A24 24 DC
K20 120 AC
L40 240 AC
J06
6 AC
Email: sales@carlingtech.com Application Support: team2@carlingtech.com
Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com
|
26
A-Series Circuit Breaker - Recessed Paddle - Dimensional Specifications
Dimensional Specifications: in. [mm]
Notes:
1
2
All dimensions are in inches [millimeters].
Tolerance ± 0.20 [.51] unless otherwise specified
Email: sales@carlingtech.com Application Support: team2@carlingtech.com
Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com
|
27
Sales Representatives, Distributors & Company Profile
Authorized Sales Representatives and Distributors
Click on a region of the map below to find your local representatives and distributors or visit
www.carlingtech.com/findarep.
CANADA
EUROPE
USA
MIDDLE
EAST
MEXICO
AFRICA
ASIA-PACIFIC
OCEANIA
SOUTH
AMERICA
About Carling
Founded in 1920, Carling Technologies is a leading manufacturer of electrical and electronic switches
and assemblies, circuit breakers, electronic controls, power distribution units, and multiplexed power
distribution systems. With four ISO registered manufacturing facilities and technical sales offices worldwide,
Carling Technologies Sales, Service and Engineering teams do much more than manufacture electrical
components, they engineer powerful solutions! To learn more about Carling please visit
www.carlingtech.com/company-profile.
To view all of Carling’s environmental, quality, health & safety certifications please visit
www.carlingtech.com/environmental-certifications
Email: sales@carlingtech.com Application Support: team2@carlingtech.com
Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com
Worldwide Headquarters
Carling Technologies, Inc.
60 Johnson Avenue, Plainville, CT 06062
Phone: 860.793.9281 Fax: 860.793.9231
@
Email: sales carlingtech.com
@
Northern Region Sales Office: nrsm carlingtech.com
@
Southeast Region Sales Office: sersm carlingtech.com
@
Midwest Region Sales Office: mrsm carlingtech.com
@
West Region Sales Office: wrsm carlingtech.com
@
Latin America Sales Office: larsm carlingtech.com
Asia-Pacific Headquarters
Carling Technologies, Asia-Pacific Ltd.,
Suite 1607, 16/F Tower 2, The Gateway,
Harbour City, 25 Canton Road,
Tsimshatsui, Kowloon, Hong Kong
Phone: Int + 852-2737-2277 Fax: Int + 852-2736-9332
@
Email: sales carlingtech.com.hk
@
Shenzhen, China: shenzhen carlingtech.com
@
Shanghai, China: shanghai carlingtech.com
@
Pune, India: india carlingtech.com
@
Kaohsiung, Taiwan: taiwan carlingtech.com
@
Yokohama, Japan: japan carlingtech.com
|
|
Europe Middle East Africa Headquarters
Carling Technologies LTD
4 Airport Business Park, Exeter Airport,
Clyst Honiton, Exeter, Devon, EX5 2UL, UK
Phone: Int + 44 1392.364422 Fax: Int + 44 1392.364477
@
Email: ltd.sales carlingtech.com
@
Germany: gmbh carlingtech.com
@
France: sas carlingtech.com
www.carlingtech.com
REV_05_2019